Modular Cleanroom Selection Starts With ISO Class, Process Risk and Scope
A modular cleanroom should not be selected only by room size. For B2B projects, the first decision is the required ISO class, the production process, the contamination risk and the responsibility boundary between the cleanroom supplier, the HVAC / EPC team and the site validation team.
YOUTH modular cleanroom systems can support hardwall, softwall, freestanding and prefabricated layouts with FFU, HEPA / ULPA filtration, cleanroom panels, doors, windows, pass boxes, air showers, flooring and gowning-area equipment. The final configuration should be confirmed according to the product process, target cleanliness class, personnel flow, material flow, installation conditions and required handover documents.

| Parameter | 15 m² | 30 m² | 50 m² | 100 m² | |
|---|---|---|---|---|---|
| Material | Option A: Aluminum profile frame / galvanized square steel (electrostatic spray) + baked enamel steel panel + hollow glass window Option B: SUS304 stainless steel frame + stainless steel panel + hollow glass window | ||||
| Class 1–100 (ISO 3–5) | FFU Qty | 12 pcs | 24 pcs | 48 pcs | 96 pcs |
| FFU Size | 1175 × 875 × 325 mm | ||||
| Air Changes | Full ceiling coverage (100% FFU coverage) | ||||
| Class 1K (ISO 6) | FFU Qty | 3 pcs | 6 pcs | 9 pcs | 18 pcs |
| FFU Size | 1175 × 875 × 325 mm | ||||
| Air Changes | 90–120 ACH (adjusted per external conditions) | ||||
| Class 10K (ISO 7) | FFU Qty | 2 pcs | 4 pcs | 6 pcs | 12 pcs |
| FFU Size | 1175 × 875 × 325 mm | ||||
| Air Changes | 60–80 ACH (adjusted per external conditions) | ||||
| Air Velocity | 0.45 m/s ± 20% | ||||
| Temperature (Recommended) | 18–28 °C | ||||
| Humidity (Recommended) | 50–70 %RH | ||||
| Illuminance | 400–800 lux | ||||
| Power | 2.4–7 kW | 4.8–10 kW | 9.6–19 kW | 19.2–30 kW | |
Modular Structure
Built with panels, frames, ceiling grids, cleanroom doors and flooring systems.
Controlled Airflow
Configured with FFU, HEPA filtration, return air and pressure control options.
Custom Layout
Designed around your production process, equipment layout and cleanroom workflow.
Expandable Design
Can be expanded, modified or upgraded as your production requirements change.
Modular Cleanroom Type Selection
Need a controlled area around a single workstation? See the Modular Clean Booth, available as a standalone product.
On a small screen, swipe or scroll horizontally inside the table to read every column. Keyboard users can focus the table area and use the arrow keys.
| Cleanroom Type | Best Fit | Limitations | Key Buying Question |
|---|---|---|---|
| Hardwall modular cleanroom | Long-term production and controlled manufacturing needing a rigid, cleanable enclosure. | May be less suitable for very temporary projects where portability is the main priority. | What pressure relationships, cleaning requirements and service life must the enclosure support? |
| Softwall cleanroom | Temporary clean areas, pilot production and clean assembly; ISO Class 6–8 may be considered where appropriate to the process and installed design. | Openings and flexible curtains may limit pressure control and cleaning options; assess suitability for regulated processes separately. | Is mobility the priority, and can the proposed arrangement meet the process and verification requirements? |
| Pharmaceutical modular cleanroom | Process-specific areas for sampling, weighing, compounding, packaging and material transfer. | Do not assume the enclosure supply includes full facility validation or all local building and utility work. | Which process requirements, flow paths and qualification documents must be included? |
| Semiconductor cleanroom module | Electronics, optics, precision assembly and other particle-sensitive production. | Chemical processes, airborne molecular contamination and specialist utilities require a defined project scope. | What particle-control target, filtration, electrostatic controls and environmental conditions does the process need? |

ISO Class Planning Before Quotation
The examples below are planning contexts, not class requirements assigned to an industry. Confirm the target class against the actual process.
On a small screen, swipe or scroll horizontally inside the table to read every column. Keyboard users can focus the table area and use the arrow keys.
| Target Cleanliness | Typical Project Use | Configuration Implication |
|---|---|---|
| ISO Class 5 | Local critical zones and selected high-cleanliness assembly or process areas. | Review whether protection is local or room-wide, the airflow arrangement, contamination sources and verification conditions. |
| ISO Class 6 | Precision manufacturing and controlled process rooms, where the process requires this class. | Coordinate filtration, air supply and return, occupancy and enclosure leakage around the intended operation. |
| ISO Class 7 | Selected support, packaging, assembly and controlled manufacturing areas. | Balance the process target with room layout, people and material movement, air design and operating needs. |
| ISO Class 8 | Selected entry, storage and general support areas, where appropriate to the process. | Define transfer routes, contamination sources and the air-system design needed to maintain the agreed target. |
ISO 14644-1 classifies air cleanliness by airborne particle concentration. The class alone does not prescribe a fixed air-change rate or ceiling filter coverage. The process owner, quality team and engineering team should agree the target and test conditions before quotation; final classification depends on the installed conditions and test results.
Industries and Applications
Pharmaceutical Manufacturing
Clean areas for material transfer, compounding, packaging, sampling and controlled production.
Medical Devices
Controlled environments for assembly, inspection, packaging and sterile device-related processes.
Laboratories and Research Facilities
Modular clean areas for laboratory preparation, sample handling and controlled experimental workflows.
Food, Cosmetics and Packaging
Clean production environments for hygiene-sensitive manufacturing and packaging operations.
Electronics and Semiconductor
Particle-controlled spaces for precision assembly, wafer-related processes and electronic component manufacturing.
Information Needed for a Modular Cleanroom RFQ
| RFQ Input | Why It Matters |
|---|---|
| Required ISO class | Determines FFU / HEPA coverage, airflow strategy and testing expectations |
| Room size and ceiling height | Defines panel system, ceiling grid, lighting, FFU quantity and installation method |
| Process and product type | Determines contamination risk, cleaning needs and material compatibility |
| Industry application | Pharmaceutical, semiconductor, medical device and laboratory projects have different priorities |
| Personnel and material flow | Affects gowning, pass box, air shower, doors and room zoning |
| Hardwall or softwall preference | Changes cost, sealing, mobility, cleanability and long-term stability |
| Required documents | Clarifies whether drawings, FAT, SAT, IQ / OQ support or material certificates are needed |
| Site responsibility boundary | Separates YOUTH supply scope from HVAC, civil work, validation and local installation work |
Compare YOUTH Projects and Prepare Your Quotation
Germany: Five Workshops, Including a Yellow-Light Room

The 198 m² Germany ISO Class 6 modular cleanroom project shows a freestanding arrangement with five workshops, including a yellow-light room. Review the room divisions, filtration, service access and process interfaces when considering a similar multi-room project.
Hungary: A Compact Three-Room Layout

The 126 m² Hungary modular cleanroom project shows three rooms and an entrance buffer in a compact arrangement, without the Germany project’s yellow-light requirement. Use the case to discuss room connections, entry and site installation for a constrained footprint.
Turn Your Requirements into a Comparable Quote
Room size is only one cost driver. Prepare the layout, target cleanliness, process equipment, environmental conditions and factory service information, then agree what is included in supply, installation and handover. The modular cleanroom cost and quotation guide explains the budget components and information needed to compare proposals.
FAQ
Can a modular cleanroom be customized?
Yes. Room size, layout, wall material, ceiling system, doors, airflow design, filtration level and supporting equipment can all be customized according to the project.
What ISO class can your modular cleanrooms support?
YOUTH can configure modular cleanrooms for common ISO-class applications such as ISO Class 5, ISO Class 6, ISO Class 7 and ISO Class 8. The final design depends on process requirements and room conditions.
Is a modular cleanroom better than traditional construction?
For many projects, modular cleanrooms offer faster installation, easier expansion, cleaner construction and better flexibility than traditional site-built cleanrooms.
Can you provide both hardwall and softwall cleanrooms?
Yes. YOUTH can provide both hardwall modular cleanrooms and softwall portable cleanrooms.
What information do you need before quoting?
The most important information includes room size, ISO class, application, process flow, equipment layout, installation location and any temperature or humidity control requirements.
Is a modular cleanroom the same as a turnkey cleanroom?
Not always. A modular cleanroom supplier can provide the cleanroom structure, panels, FFU / HEPA filtration, doors, windows, pass boxes, air showers and related equipment. HVAC, building utilities, civil work and final validation may require the buyer’s engineering team, EPC contractor or local validation team. The project scope should be confirmed before quotation.
What is the biggest mistake when requesting a modular cleanroom quote?
The biggest mistake is asking only for a room size without defining ISO class, process type, personnel flow, material flow, pressure strategy, equipment list and document requirements. This usually creates repeated clarification and makes supplier quotations difficult to compare.